- Single-phase uninterruptible power supplies - On-line double conversion with DSP tecnology (Digital Signal Processor) - MISSION UPS is equipped with a LCD display to shows all parameters (more than 50 items), and is possible to set the most basic configurations directly on LCD display - MISSION is a compact UPS, and can be used for all kind of applications - It is a true on-line transformerless UPS, double conversion technology, single phase - It includes a maintenance bypass (6KVA and 10KVA models), and it is possible to increase the back-up time by adding battery packs - MISSION is the most suitable product for critical loads - It has 0 ms switching time and guarantee a perfect protection for all applications requiring an input voltage without disturbances and no interruptions - A PF at 0.8 and DSP technology (Digital Signal Processor) it provides high output efficiency for all kind of loads Features - High input and output PF - Wide input voltage range (energy saving) - Eco Mode (Economic operation mode) - Back feed protection and Surge Protection - Auto self test - Cold Start - Parallel operation capability - Output By-pass - Additional battery pack - USB - EPO - Software included - Intelligent Slot SNMP board (optional) - Dry contact (optional) Specifications - Nominal Power: 2000 VA / 1600 W - Input: Single-phase + GND - Voltage Range: * 115 +/- 5VAC * 295 +/- 5VAC - Frequency Range: * 45Hz-55Hz@50HZ * 55Hz-65Hz@60HZ - Power Factor: =>0.98 - ECO interval: Output voltage +/- 20 VAC - Bypass range: 186 VAC - 252 VAC - THDi: <=7% (100% non linear load) - Connection: 1× IEC - Output: Single-phase + GND - Nominal Voltage: 208/220/230/240 VAC - Power Factor: 0.8 - Voltage tolerance: +/- 2% - Frequency: * Normal operation: When input frequency is within its range, then output frequency is the same than input; When input frequency is out of its range, then output frequency is (50/60 +/-0.2)Hz, which is the same as in battery mode * Battery operation: (50/60 +/-0.2)Hz - Crest Factor: 3:1 - Switching time: Rete - battery = 0ms - Overload: * Battery operation: ** 108% +/-5% < load <= 150% +/-5% >30s output shutdown and signal ** 150% +/-5% < load < 200% +/-5% >300ms output shutdown and signal * Normal operation: ** 108% +/-5% < load <=150% +/-5% >30s switch to bypass and signal ** 150% +/-5% < load <200% +/-5% >300ms switch to bypass and signal - Efficiency: * Normal operation: 100% of load =>88% * Battery operation: 100% of load =>85% * ECO: 100% of load =>94% - Output voltage distortion: * <= 3% (100% linear load) * <= 5% (100% non linear load) - Outlet type: 3× IEC, 2× Schuko - Input battery voltage: 48 VDC - Number of internal batteries: 4 - Type of battery: 12V/7AH battery maintenance-free, sealed lead acid (referred to UPS standard only) - Autonomy time: Full load =>4min (referred to UPS standard only), for long autonomy times models, the autonomy is defined by the battery capacity - Recharge current: 1A - Environmental conditions: * Temperature: 0°C - 40°C (battery excluded) * Humidity: 0 - 95% whitout condensation * Max Operating altitude: < 1500m; if >1500m, output power reduced - Storage temperature: -25°C - 55°C (battery excluded) - Dimensions (W×D×H): 191×469×339 mm - Weight: 20 kg